1.
Article in English | IMSEAR | ID: sea-111462

ABSTRACT

The purpose of this study was to evaluate the effect of fluence map editing in electronic tissue compensator (ETC) on the dose homogeneity for head and neck cancer patients. Treatment planning using 6-MV X-rays and bilateral field arrangement employing ETC was carried out on the computed tomography (CT) datasets of 20 patients with head and neck cancer. All the patients were planned in Varian Eclipse three-dimensional treatment planning system (3DTPS) with dynamic multileaf collimator (DMLC). The treatment plans, with and without fluence editing, was compared and the effect of pre-editing and post-editing the fluence maps in the treatment field was evaluated. The skin dose was measured with thermoluminescent dosimeters (TLDs) and was compared with the skin dose estimated by TPS. The mean percentage volume of the tissue receiving at least 107% of the prescription dose was 5.4 (range 1.5-10; SD 2.4). Post-editing fluence map showed that the mean percentage volume of the tissue receiving at least 107% of the prescription dose was 0.47 (range 0.1-0.9; SD 0.3). The mean skin dose measured with TLD was found to be 74% (range 71-80%) of the prescribed dose while the TPS showed the mean skin dose as 85% (range 80-90%). The TPS overestimated the skin dose by 11%. Fluence map editing thus proved to be a potential tool for improving dose homogeneity in head and neck cancer patients planned with ETC, thus reducing the hot spots in the treatment region as well. The treatment with ETC is feasible with DMLC and does not take any additional time for setup or delivery. The method used to edit the fluence maps is simple and time efficient. Manual control over a plan is essential to create the best treatment plan possible.


Subject(s)
Dose-Response Relationship, Radiation , Feasibility Studies , Head and Neck Neoplasms/diagnostic imaging , Humans , Radiometry/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/instrumentation , Radiotherapy, Intensity-Modulated , Time Factors , Treatment Outcome
2.
J Cancer Res Ther ; 2008 Apr-Jun; 4(2): 88-90
Article in English | IMSEAR | ID: sea-111396

ABSTRACT

The purpose of this study was to measure the multileaf collimator (MLC) transmission from the first Hi-Art II tomotherapy machine installed at the Advanced Center for Treatment, Research, and Education in Cancer (ACTREC). The MLC transmission was measured with an A1SL ion chamber and the radiographic extended dose range (EDR2) film in virtual water slabs at 1.5-cm depth with a source-to-surface distance of 85 cm. The MLC transmission was measured for 30 s with all leaves open and for 360 s with all leaves closed. The movable jaws were set to the calibration field size of 5 x 40 cm at isocenter. The MLC transmission was found to be 0.3% with the ion chamber and 0.32% with the film. Thus, the MLC transmission value was found well within the manufacturer tolerance of 0.5%. MLC can safely be used for the beam modulation during intensity-modulated radiotherapy (IMRT) to deliver accurate doses to the patients.


Subject(s)
Equipment Design , Film Dosimetry , India , Radiotherapy/instrumentation , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated/instrumentation
3.
J Cancer Res Ther ; 2007 Jul-Sep; 3(3): 140-2
Article in English | IMSEAR | ID: sea-111477

ABSTRACT

PURPOSE: To estimate the transit dose from motorized wedge (MW) treatment in Equinox-80 telecobalt machine. MATERIALS AND METHODS: Two plans were generated in Eclipse treatment planning system with universal wedge (UW) and MW each for 10 x 10 cm 2 . The transit dose was measured with 0.6 cc cylindrical ion chamber and thermoluminescent dosimeters (TLD) chips at a depth of 5 cm with source to axis distance (SAD) 80 cm. RESULTS: The measured dose with ion chamber was in well agreement with the calculated dose from Eclipse within +/- 2%. The planned dose was 100 cGy while the measured absorbed dose with ion chamber for 15 degrees , 30 degrees , 45 degrees and 60 degrees MW treatment was found to be 100.94, 101.04, 100.72 and 99.33 cGy respectively. For 15 degrees , 30 degrees , 45 degrees and 60 degrees UW treatment, the measured absorbed dose was 99.33, 97.67, 97.77 and 99.57 cGy respectively. Similarly the measured absorbed dose with TLD was within +/- 3% with the planned dose for universal wedge (UW) and MW. From the experimental measurements, it was found that there was no significant contribution of transit dose during MW treatment. CONCLUSION: The actual measurements carried out with ion chamber in Equinox-80 machine for UW and MW revealed no variation between the doses delivered. The doses were comparable for both UW and MW treatments. The results from TLD measurements additionally confirmed no variation between the doses delivered with UW and MW. It was also demonstrated that the observed excess or less transit dose with MW does not have any significant clinical impact. This assured the safe dose delivery with MW.


Subject(s)
Humans , Neoplasms/radiotherapy , Phantoms, Imaging , Radioisotope Teletherapy/instrumentation , Radiotherapy Planning, Computer-Assisted , Thermoluminescent Dosimetry